[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/e5465080305e17593ee177f6c3d0e304_1730085929.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg)
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/9a29a44edf8ddf5e6f38124ff7ae6bbe_1730086034.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg&type=1)
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/d6a1ddd52157f23a5b938442e3d81723_1730086034.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg&type=1)
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/d784ab78ab2df8844fe0fb8c553f1bb9_1730184814.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg&type=1)
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/18606344b1b9cbc6bd0a76151b4d9890_1734592124.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg&type=1)
![[ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R [ CU-XPU13XKH-1 ] Panasonic Outdoor PCB Board ACXA73C79300R](https://cdn1.npcdn.net/images/1e1e8fa47ca3a627cd683451113642f4_1734592124.webp?md5id=1cfcf0911a356ff7dec8682d2c5cdbaa&new_width=1000&new_height=1000&size=max&w=1698724117&from=jpeg&type=1)
Wall Mounted Outdoor Parts
ACXA73C79300R Electronic Controller - Main
CU-XPU13XKH-1
H11 error code
1. Faulty outdoor unit PCB .
2. Faulty indoor unit PCB .
3. Indoor-outdoor singnal transmission error due to wrong wiring .
4. Indoor-outdoor singnal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units .
5. Indoor-outdoor singnal transmission error due to disturbed power supply waveform .
Panasonic Error Code F90 Power factor correction (PFC circuit protect)
1. DC voltage peak due to power supply surge .
2. DC voltage peak due to compressor windings not uniform
Panasonic Error Code F93 Outdoor compressor abnormal revolution
1. Compressor terminal disconnect .
2. Outdoor PCB malfunction .
Panasonic Error Code F99 Outdoor direct current peak detection.
1. DC current peak due to compressor failure .
2. DC current peak due to defective power transistor (IPM)
3. DC current peak due to defective outdoor unit PCB .
4. DC current peak due to short circuit .
Any question feel free to contact us .
( Kami membekalkan semua bahagian untuk penghawa dingin Panasonic. )
We deliver to all states in Malaysia .
Panasonic Error Code H11 Indoor/Outdoor Abnormal Communication